For: PG residents · Optometrists
Last updated: November 2026
Key points in 60 seconds
NPA and NPC are among the quickest tests in the clinic, and among the easiest to get wrong. This page covers how to do both, the normal values, what they are used for, and the common problems with practical fixes.
For other accommodation tests (MEM and Nott retinoscopy, facility, NRA and PRA), see Accommodation Testing.
What it measures: the closest point at which a small target stays clear, using all available accommodation. Its reciprocal gives the amplitude of accommodation.
| Method | How | Notes |
|---|---|---|
| Push-up | Target moved towards the eye until first sustained blur | Quick; overestimates amplitude by about 1–2 D because the target gets bigger as it comes closer and depth of field adds to it |
| Push-down (pull-away) | Target moved away from the eye until it first clears | Gives a slightly lower value; averaging both reduces error |
| Minus lens | Target fixed at 40 cm; minus lenses added in 0.25 D steps until sustained blur. Amplitude = total minus added + 2.50 D | No change in target size; more repeatable, but gives a lower value than push-up |
| RAF near point rule | A ruler with a sliding target, resting on the cheeks | Measures NPA and NPC with one device; note whether the scale reads from the cornea or the spectacle plane |
Expected amplitude (Hofstetter): minimum = 15 − 0.25 × age; average = 18.5 − 0.3 × age; maximum = 25 − 0.4 × age. For a 10-year-old the minimum is about 12.5 D (NPA about 8 cm); at 40 years about 5 D (20 cm); by about 55 years under 2 D.
What it measures: the closest point at which both eyes can keep a target single. It tests fusional convergence and is the core sign of convergence insufficiency.
Expected values: break at about 5 cm or closer, with recovery about 7 cm. A break further than 6 cm was the cut-off used for convergence insufficiency in the CITT trials; in concussion assessment a near point of 5 cm or more is usually treated as abnormal.
| Test | Example |
|---|---|
| NPA | NPA with distance Rx, push-up, N5 target, from spectacle plane: RE 9 cm (11 D), LE 9 cm (11 D), BE 8 cm (12.5 D) |
| NPC | NPC accommodative target: break 9 cm, recovery 12 cm; receding to 14 cm after 5 repetitions; red-green penlight break 13 cm |
| Problem | Effect | Fix |
|---|---|---|
| Uncorrected refractive error | A hyperope seems to have little amplitude; a myope seems to have a lot | Always test with the full distance correction |
| Target too large | Blur noticed late, so amplitude is overestimated | Use a line just above threshold (N5–N6) or a fine line target |
| Moving too fast | The patient reports blur after the true near point has passed | Move about 1–2 cm per second; repeat and average |
| Small pupils and bright light | Larger depth of field inflates the amplitude | Use moderate room lighting; note it |
| "Blur" or "double" misunderstood | Inconsistent end points, especially in children | Demonstrate first; in children watch for the eye drifting out at the NPC break |
| Different measuring points | Results cannot be compared between visits or clinics | State whether from the cornea, spectacle plane or bridge of the nose, and keep to one |
| Only one attempt at NPC | Poor stamina is missed | Repeat 3–5 times and use a red-green penlight test |
| Testing one eye only for NPA | Unequal accommodation (for example from Adie pupil) is missed | Test each eye, then both |
| Patient fatigue late in the day | Lower values than in the morning | Note the time; repeat at a later visit if borderline |
Where students slip
Related: Accommodation testing, Accommodative anomalies and vision therapy, Subjective refraction routine, CITT trial.
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
How to cite this page
Patel D. Near Point of Accommodation and Convergence (NPA and NPC): Methods, Normal Values, Uses and Pitfalls. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/near-point-accommodation-convergence-npa-npc.html. Accessed [date].
Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.