8 wet-lab drills, each with a clear aim, steps, common faults with fixes, and a self-check list.
Do one drill many times rather than many drills once; move on only when you pass the self-check several times in a row.
Record your session through the microscope and review it with a senior.
Treat animal eyes as biological waste and wear eye protection.
These drills turn wet-lab time into measurable progress. Use them alongside the wet-lab training guide, which covers practice eyes, setting up a station and the overall skill ladder.
Drill 1: Microscope and two-hand control
Aim: Get comfortable with focus, centring, the foot pedal and using both hands under the microscope.
Set eyepieces to your refraction and the interpupillary distance; adjust seat height so your forearms rest on the table.
Place a goat eye in the holder. Centre and focus on the cornea with the foot pedal, without looking away from the eyepieces.
With fine forceps in each hand, pick up and transfer a small piece of suture from one side of the cornea to the other, ten times.
Repeat with your non-dominant hand leading.
Fault
Fix
Image drifts out of focus
Rest your wrists; use the pedal, not your head, to refocus.
Tremor
Support the ulnar side of both hands on the eye holder or wrist rest.
Self-check (tick all before moving on):
☐ Field stays centred and focused throughout
☐ Ten transfers without dropping the suture
☐ Both hands used equally
Drill 2: Clear corneal incision
Aim: Make a three-plane, self-sealing clear corneal incision and side ports.
Firm the globe (inject saline or viscoelastic through a side port if soft).
Make a 1 mm side port with a 15° knife about 60–90° from the main wound.
With the keratome, make a shallow vertical groove, then advance in the plane of the cornea for about 2 mm, then dip into the chamber.
Fill the chamber with saline; press on the posterior lip with a cannula and check for leaks with fluorescein.
Fault
Fix
Tunnel too short or leaks
Keep the blade flat for longer before dipping in.
Premature entry
Keep the heel of the blade up and the eye firm.
Descemet detachment
Advance the blade fully into the chamber before withdrawing; do not enter twice.
Self-check (tick all before moving on):
☐ Wound width matches the keratome
☐ Tunnel length about 1.75–2 mm
☐ Watertight on pressure ten times in a row
Drill 3: Scleral tunnel for small-incision surgery
Aim: Make a frown or straight scleral tunnel and a corneal pocket for manual small-incision surgery.
Fornix-based conjunctival flap; light cautery.
Partial-thickness scleral groove (about one-third depth) 1.5–2 mm behind the limbus, about 6–7 mm long.
Dissect forward with a crescent knife in one plane, 1–1.5 mm into clear cornea; widen the inner pocket.
Enter with a keratome and enlarge the internal opening wider than the external.
Fault
Fix
Button-holing the roof
Groove deeper; keep the crescent bevel up and flat.
Premature entry
Do not dip the tip; sweep side to side.
Too deep (scleral perforation)
Stop, regroove more superficially.
Self-check (tick all before moving on):
☐ Even thickness of the roof
☐ Internal opening wider than external
☐ Self-sealing at the end
Drill 4: Capsulorhexis
Aim: Make a round, centred, continuous curvilinear capsulorhexis of 5–5.5 mm.
Stain the capsule with trypan blue under air, then fill with viscoelastic.
Start a central flap with a cystitome (bent 26G needle).
Fold the flap over and tear in small steps, regrasping close to the tear front every 90°.
Mark the target size first with a corneal marker or use the pupil as a guide.
Fault
Fix
Run-out to the periphery
Deepen the chamber with more viscoelastic, flatten the lens, pull the flap back towards the centre (Little technique).
Too small
Enlarge with a second spiral tear after IOL insertion.
Elastic capsule in young goat eyes
Use more viscoelastic and smaller steps; this capsule is harder than in a human cataract.
Self-check (tick all before moving on):
☐ Round and centred
☐ Size within 0.5 mm of target
☐ No run-out in ten consecutive eyes
Drill 5: Hydrodissection and rotation
Aim: Free the nucleus from the cortex and rotate it in the bag.
Lift the capsulorhexis edge with the cannula tip just under the anterior capsule.
Inject a slow steady stream of saline until a fluid wave crosses the red reflex.
Press gently on the centre of the nucleus to push fluid round and release the bag.
Rotate the nucleus with a second instrument in both directions.
Fault
Fix
No fluid wave
Move the cannula further under the capsule edge.
Capsule blow-out
Inject slowly, and decompress the nucleus between injections.
Self-check (tick all before moving on):
☐ Visible fluid wave
☐ Nucleus rotates freely 360° both ways
☐ No capsule damage
Drill 6: Nucleus management: groove and chop
Aim: Practise phaco sculpting and chopping on a hardened lens.
Harden the lens following your wet lab's protocol (for example brief microwave heating or a fixative injection).
Sculpt a central groove one and a half phaco-tip widths wide and deep enough to crack.
Crack into two halves; rotate and chop each half into quadrants.
Bring each fragment to the centre and emulsify it away from the endothelium and posterior capsule.
Fault
Fix
Groove too shallow to crack
Sculpt deeper centrally where the nucleus is thickest.
Chopper catching the capsule
Keep the chopper under the anterior capsule edge, tip horizontal until it reaches the nucleus edge.
Wound burn
Keep flow up; use pulse or burst mode; do not occlude the sleeve.
Self-check (tick all before moving on):
☐ Clean crack in two
☐ Four quadrants removed with the posterior capsule intact
☐ Energy used falls across sessions
Drill 7: IOL injection and dialling
Aim: Load and inject a foldable IOL and centre it in the bag.
Load the IOL into the cartridge with viscoelastic, haptics in the correct orientation.
Insert the cartridge bevel-down into the wound and inject slowly, guiding the leading haptic into the bag.
Dial the trailing haptic into the bag with a Sinskey hook.
Remove the viscoelastic from behind and in front of the IOL.
Fault
Fix
IOL flips upside down
Check haptic orientation in the cartridge before injecting.
Trailing haptic stuck in the wound
Push it down and in with the hook, then rotate.
Self-check (tick all before moving on):
☐ IOL in the bag and centred
☐ Correct side up
☐ No capsule tear
Drill 8: Corneal suturing
Aim: Place and bury interrupted 10-0 nylon sutures in the cornea.
Make a 3 mm full-thickness corneal laceration on a firm eye.
Enter perpendicular to the cornea about 1 mm from the wound edge at about 90% depth; exit at the same depth and distance on the other side.
Tie a 3-1-1 knot (or 2-1-1) with tying forceps; tension just enough to close the wound.
Trim close to the knot and rotate it into the needle track to bury it.
Fault
Fix
Sutures too shallow (leak)
Enter vertically, then turn the needle along its curve.
Too tight (flattening, astigmatism)
Close with gentle tension; check the wound with fluorescein.
Knot will not bury
Rotate towards the side where the suture is longer.
Self-check (tick all before moving on):
☐ Equal bites both sides
☐ Depth about 90%
☐ Watertight wound with buried knots
Logbook columns
Date
Eye type
Drill
Attempts
Passed self-check?
Main fault
Change next time
Common mistakes
Practising on a soft eye: incisions feel nothing like theatre.
Jumping to full cases before each step is reliable.
International Council of Ophthalmology: ICO-OSCAR surgical competency rubrics
American Academy of Ophthalmology. Basic and Clinical Science Course, Section 11: Lens and Cataract, 2025–2026