All 39 optics, refraction and low vision theory questions from the MD, MS and DNB question bank, grouped by topic. Tap a question to open its model answer outline. Every question links to the pages on this site to revise it from.
How to use this page: read the question, write or say your own answer in about ten minutes (introduction, classification, features, investigations, management, recent advances, one diagram), then open the outline and compare. The outlines show the points examiners look for; they are not word-for-word answers. Questions are as recalled by candidates, not official papers.
HIGH-YIELD asked often: prepare these first. DNB / UNIV asked in DNB and other university exams. NEW added in the 2026 update: likely future questions.
Physiological Optics & Aberrations
OP 1. Schematic and reduced eye (Gullstrand, Donders) — cardinal points, with diagrams; the aphakic schematic eye. HIGH-YIELD· outline
Gullstrand’s schematic eye
Six cardinal points: two principal points (about 1.35 and 1.60 mm behind the cornea), two nodal points (about 7.08 and 7.33 mm), anterior focal point (−15.7 mm) and posterior focal point (24.4 mm).
Total power about +58.6 D (cornea about +43 D, lens about +19 D in situ); refractive indices: cornea 1.376, aqueous 1.336, lens 1.386–1.406, vitreous 1.336.
Reduced eye (Listing, Donders)
Single refracting surface with one principal point (1.35 mm) and one nodal point (7.08 mm behind the cornea), power about +58–60 D, axial length about 22.6–24 mm.
Use: calculating retinal image size (about 0.015 mm per minute of arc) and the visual angle.
Aphakic schematic eye
Lens removed: power about +43 D, about +10 to +12 D hypermetropia; magnification about 25–30% with spectacles (aniseikonia), less with contact lenses (7–9%) and minimal with IOLs.
OP 2. Pinhole and stenopaic slit; angle kappa; Purkinje-Sanson images; Stiles-Crawford effect and Purkinje shift. DNB / UNIV· outline
Pinhole
Small aperture (about 1.2 mm) allows only central rays, increasing depth of focus; improvement means refractive error; no improvement suggests media or retinal disease (pinhole may worsen vision in macular disease).
Stenopaic slit
Slit (about 1 mm) used to find the axis of astigmatism, to assess optical iridectomy site and in irregular astigmatism.
Angle kappa
Angle between the visual axis and the pupillary axis; positive kappa (nasal displacement of corneal reflex) gives pseudo-exotropia; relevant for multifocal IOL centration and refractive surgery.
Purkinje–Sanson images
Four reflections: I anterior cornea (upright, brightest), II posterior cornea, III anterior lens (largest, upright, moves with accommodation), IV posterior lens (inverted); uses: accommodation studies, eye trackers, Hirschberg test, IOL tilt.
Stiles–Crawford effect
Light entering the pupil centre is more effective in stimulating cones than peripheral rays (waveguide nature of cones); reduces aberrations of large pupils.
Purkinje shift
Change in peak spectral sensitivity from 555 nm (photopic) to 507 nm (scotopic) in dim light: red appears darker, blue-green brighter.
OP 3. Sturm's conoid — definition, interval and clinical applications. DNB / UNIV· outline
Sturm’s conoid
The shape of the bundle of rays refracted by an astigmatic (toric) lens: two focal lines at right angles separated by an interval, with the circle of least confusion between them.
Interval of Sturm
Distance between the two focal lines; proportional to the amount of astigmatism.
Clinical applications
Classification of astigmatism (simple, compound, mixed by position of focal lines relative to the retina).
Spherical equivalent places the circle of least confusion on the retina (best compromise vision).
Jackson cross-cylinder, fan and block tests, astigmatic dial.
Fogging technique: both lines placed in front of the retina so the patient’s accommodation does not interfere.
OP 4. Optical aberrations of the eye — spherical, chromatic and higher-order; spectacle-induced aberrations and their minimisation. HIGH-YIELD· outline
Monochromatic aberrations
Spherical: peripheral rays focus more strongly; reduced by the pupil, the aspheric cornea and lens grading; increases after myopic LASIK.
Coma, oblique astigmatism, field curvature, distortion (barrel, pincushion).
Chromatic aberration
Blue focuses in front of red (about 2 D difference); basis of the duochrome test.
Higher-order aberrations
Zernike polynomials: coma, trefoil, spherical aberration; measured by wavefront aberrometry (Hartmann–Shack); increased in keratoconus, after refractive surgery; cause haloes and glare.
Spectacle-induced aberrations and minimisation
Oblique astigmatism and curvature of field in strong lenses: best-form (meniscus) lenses, aspheric and lenticular designs.
Prismatic effects and chromatic dispersion: high-Abbe materials, correct centration and vertex distance, smaller frames.
Therapeutic: diplopia in decompensating phorias and paralytic squint, convergence insufficiency exercises, nystagmus (null point shift, induced convergence), field expansion in hemianopia (Peli prisms).
OP 7. Wavefront analysis and higher-order aberrations — principles and clinical applications. · outline
Wavefront analysis
Measures the shape of the light wave leaving (or entering) the eye compared with an ideal plane wave; Hartmann–Shack sensor (lenslet array) or Tscherning and ray tracing.
Zernike polynomials
Lower-order aberrations: defocus (sphere) and astigmatism.
Higher-order aberrations: coma (decentred cornea, keratoconus), trefoil, spherical aberration (large pupils, night vision, after myopic LASIK), secondary astigmatism; RMS value expresses total error.
Clinical applications
Wavefront-guided and wavefront-optimised LASIK and PRK; aspheric IOL selection (negative spherical aberration IOLs balance positive corneal spherical aberration); assessment of keratoconus, night vision complaints, dry eye; contact lens design; adaptive optics imaging of photoreceptors.
Refraction & Refractive Errors
OP 8. Discuss streak retinoscopy and the subjective verification of refraction. Principles and pitfalls of autorefraction. HIGH-YIELD· outline
Streak retinoscopy
Principle: observe the reflex from the patient’s pupil; neutralise with lenses (with movement: add plus; against movement: add minus); subtract the working distance (for example 1.5 D at 67 cm).
Find the two principal meridians for astigmatism (break, width, skew); cycloplegia in children.
Subjective verification
Fogging, best vision sphere, duochrome, Jackson cross-cylinder for axis and power, binocular balancing (prism dissociation or alternate occlusion), near addition.
Pitfalls: instrument (proximal) myopia, accommodation in young patients, media opacities, small pupils, irregular corneas, poor fixation; always verify subjectively.
OP 9. Jackson cross cylinder — uses in refraction. HIGH-YIELD· outline
Jackson cross cylinder
A combination of a plus and a minus cylinder of equal power at right angles (for example ±0.25 D); handle at 45° to the axes.
Uses
Refining cylinder axis: place handle along the cylinder axis, flip, rotate the axis towards the better position (towards the plus axis for plus cylinders).
Refining cylinder power: align the cross-cylinder axes with the correcting cylinder, flip, add or reduce cylinder; maintain spherical equivalent.
Checking for astigmatism when none is found; near add assessment (fused cross-cylinder).
Based on chromatic aberration: red light (longer wavelength) focuses behind green; the patient compares letters on red and green backgrounds.
Interpretation
Letters clearer on red: under-corrected myope or over-plussed hyperope (add minus).
Clearer on green: over-corrected myope (add plus).
Equal: correct.
Uses and limitations
Refining spherical end-point in subjective refraction; works in colour-deficient patients (relies on wavelength, not colour naming); less reliable in older patients (yellow lens), with pupil size changes, and when vision is worse than 6/12.
Both focal lines lie on the same side of the retina: compound myopic astigmatism (both in front) or compound hypermetropic astigmatism (both behind).
Correction
Spherocylindrical lens, e.g. −2.00 DS/−1.00 DC × 180 (compound myopic) or +2.00 DS/+1.00 DC × 90 (compound hypermetropic).
Notes
Transposition: change sign of cylinder, add cylinder to sphere, rotate axis by 90°.
Compare with simple (one line on the retina) and mixed (one line in front and one behind) astigmatism.
OP 12. Types of astigmatism and the basic principles applied in its management and correction. HIGH-YIELD· outline
Types
Regular (principal meridians at 90°): with-the-rule, against-the-rule, oblique.
By focal points: simple, compound, mixed myopic or hypermetropic.
Irregular: keratoconus, scars, post-surgical.
Corneal vs lenticular vs total.
Principles of correction
Full correction in children (amblyopia prevention); in adults, partial correction or rotating the axis towards 90° or 180° to reduce distortion; maintain spherical equivalent.
Spectacles (toric, minus cylinder), soft toric or RGP contact lenses (irregular astigmatism), toric IOLs, limbal relaxing incisions, LASIK, PRK and SMILE, corneal cross-linking and ring segments in keratoconus.
OP 13. Hypermetropia — classification (manifest, latent), uncovering latent hypermetropia, and spectacle prescription. DNB / UNIV· outline
Classification of hypermetropia
Axial, curvature, index, positional (posterior IOL), absence of lens (aphakia).
Total hypermetropia (under cycloplegia) = latent (corrected by ciliary tone) + manifest; manifest = facultative (overcome by accommodation) + absolute (cannot be overcome).
Uncovering latent hypermetropia
Cycloplegic refraction (cyclopentolate 1% or atropine in young children), fogging techniques, repeated refraction over time with gradual acceptance of plus lenses.
Spectacle prescription
Children: full cycloplegic correction if esotropia; otherwise moderate under-correction (e.g. reduce by 1 D symmetrically) with amblyopia and symptoms considered; treat anisometropia.
Adults: maximum plus accepted for clear distance vision (manifest); increase gradually; near add when presbyopic.
Complications if untreated: accommodative esotropia, amblyopia, asthenopia, angle closure in adults (small eyes).
OP 14. Anisometropia — definition, significance and management. · outline
Definition
Difference in refractive error between the two eyes (clinically significant if 1 D or more in sphere or astigmatism).
Significance
Amblyopia (hyperopic anisometropia worse: the more hyperopic eye is never in focus), loss of binocularity and stereopsis, aniseikonia (image size difference: about 1% per dioptre with spectacles), prismatic effects when looking away from optical centres (vertical imbalance at near), asthenopia.
Management
Children: full spectacle correction plus amblyopia therapy; contact lenses for large differences; refractive surgery in selected cases.
Adults: spectacles if tolerated (up to about 3–4 D), contact lenses (reduce aniseikonia in axial anisometropia less, Knapp rule), refractive surgery or lens surgery; slab-off prism for vertical imbalance at near.
Difference in the perceived size or shape of images between the two eyes; up to about 5% is tolerated.
Types
Optical (static: refractive, induced by spectacles; dynamic: prismatic) and retinal (macular disease: ERM causes macropsia; macular oedema: micropsia).
Causes
Anisometropia, aphakia corrected by spectacles (about 25–30% magnification), unilateral pseudophakia mismatch, refractive surgery in one eye, retinal disease.
Symptoms and assessment
Asthenopia, diplopia, distortion of space, headache; measured with the space eikonometer or new aniseikonia test.
Management
Contact lenses or IOL, iseikonic (size) lenses (changing base curve, thickness, vertex distance), refractive surgery; treat the retinal cause.
OP 16. Aphakia — problems of aphakic vision (jack-in-the-box phenomenon) and modalities of correction. DNB / UNIV· outline
Problems of aphakic vision with spectacles
Magnification (about 25–33%), difficulty judging distances, pincushion distortion, ring scotoma (prismatic effect at lens edge causes a ring of missed field) and jack-in-the-box phenomenon (objects appear and disappear as gaze moves), restricted field, spherical aberration, heavy thick lenses, loss of accommodation, unilateral aphakia: diplopia (aniseikonia).
Modalities of correction
Spectacles (high plus lenticular or aspheric lenses), contact lenses (magnification about 7–10%), intraocular lenses (best: secondary IOL in the bag, sulcus, iris-claw, scleral-fixated or glued IOLs), epikeratophakia and refractive keratoplasty (historical).
OP 17. Selection of cycloplegics and mydriatics in refraction. · outline
Choosing a cycloplegic
Atropine 1% (ointment, twice daily for 3 days or drops): strongest; children under 5 years with esotropia or suspected latent hypermetropia; allowance (subtract about 1 D) for ciliary tone.
Cyclopentolate 1% (two doses 5–10 minutes apart; refract at 30–45 minutes): routine in children over 1 year (0.5% in infants); allowance smaller.
Homatropine 2%: older children (rarely used now).
Tropicamide 1%: adults and older children (weak cycloplegia, good mydriasis).
Mydriatics for fundus examination
Tropicamide 1% with phenylephrine 2.5% (10% avoided in infants, cardiac patients); in preterm babies: dilute combinations (cyclopentolate 0.2% with phenylephrine 1%).
Precautions
Check the angle (shallow AC), allergy, systemic side effects (punctal occlusion), dark irides need more drops, warn about blurring and photophobia.
Pre-operative prognosis before cataract surgery or keratoplasty in dense media; counselling.
OP 20. Discuss the changing concepts in the management of myopia (including pathological high myopia), with a clinical appraisal of the merits and demerits of the methods available. HIGH-YIELD· outline
Changing concepts
Myopia is epidemic (about half of the world by 2050); now treated to slow progression, not only corrected.
Methods to slow progression
Low-dose atropine (0.01–0.05%; LAMP study: 0.05% most effective).
OP 21. Spectacle lenses — bifocal designs, progressive-power and toric lenses; centration, decentration and back-vertex distance. HIGH-YIELD· outline
Bifocals
Fused (round-top, flat-top/D-segment), executive (one-piece); image jump and prismatic effect at the segment line; flat-top reduces image jump.
Progressive addition lenses
Gradually increasing plus power down the corridor; distance, intermediate and near zones; peripheral unwanted astigmatism (Minkwitz theorem); adaptation required.
Toric lenses
Correct astigmatism; minus cylinder form on the back surface (less distortion).
Centration and decentration
Optical centres aligned with the pupils (interpupillary distance); deliberate decentration creates prism (Prentice rule); vertical imbalance in anisometropia (slab-off).
Back-vertex distance
Effective power changes with distance from the eye for lenses over ±4 D: Fe = F / (1 − dF); plus lenses moved forward act stronger.
OP 22. Computer vision syndrome; asthenopia and eye strain. DNB / UNIV· outline
Computer vision syndrome (digital eye strain)
Eye and vision symptoms related to prolonged screen use.
Causes
Reduced and incomplete blinking (dry eye), uncorrected refractive error and presbyopia, accommodative and convergence stress, glare and poor ergonomics, blue light (not proven harmful).
20-20-20 rule (every 20 minutes, look 20 feet away for 20 seconds), correct refraction (computer glasses for intermediate distance), lubricants, blink exercises, screen slightly below eye level at 50–70 cm, reduce glare, humidity, treat binocular vision problems (convergence insufficiency).
Asthenopia
Symptoms of eye strain from refractive error, binocular vision anomalies, dry eye, poor lighting, systemic factors (stress, sleep).
OP 23. Space myopia, night myopia and pseudomyopia. DNB / UNIV· outline
Space (empty field) myopia
Myopic shift (about 1 D) when looking at a featureless field (sky, fog) as accommodation rests at its tonic position; pilots and astronauts.
Night myopia
Myopic shift in dim light (0.5–1.5 D): spherical aberration from large pupils, Purkinje shift towards shorter wavelengths, tonic accommodation; correct with a small minus lens for night driving.
Pseudomyopia
Apparent myopia from excessive accommodation (ciliary spasm): near work, stress, uncorrected hyperopia, convergence excess, drugs (miotics, sulphonamides), uveitis; refraction under cycloplegia shows less myopia or hyperopia; treat with cycloplegia, correct hyperopia, vision therapy.
OP 24. Myopia control in children — low-dose atropine, myopia-control spectacle lenses, orthokeratology and outdoor time: evidence and practice. · outline
Low-dose atropine
0.01–0.05% at night; LAMP study: 0.05% most effective (slows progression by about 50%) with acceptable side effects; ATOM 1 and 2; rebound on stopping is smaller with low doses.
Orthokeratology (overnight rigid lenses reshape the cornea; slows axial growth by about 40–50%; infection risk), dual-focus soft lenses (MiSight: about 50–59% slowing in 3 years).
Outdoor time
At least 2 hours daily delays onset of myopia (light exposure, dopamine); 20-20-20 rule for near work.
Practice
Start treatment in progressing myopes, monitor axial length every 6 months, combine methods (atropine with ortho-k), counsel on adherence and cost; red-light therapy is under evaluation with safety concerns.
OP 38. Prescribing spectacles in practice — children, anisometropes and older patients; partial prescriptions and adaptation to cylinders. NEW· outline
General principles
Prescribe for the patient’s visual needs and symptoms, not just the numbers; compare with the old prescription; avoid large changes at once; give a trial frame for big changes.
Children
Cycloplegic refraction; full correction of hyperopia in esotropia; correct significant myopia, astigmatism (1.5 D or more) and anisometropia (1 D or more) because of amblyopia risk.
Guidelines (AAO PPP): treat hyperopia over +4.5 D at 1 year; age-based thresholds; small hyperopia in a straight eye may be left uncorrected.
Polycarbonate or Trivex lenses for safety; good frame fit (sports bands); regular review.
Anisometropes
Children: full correction (they adapt), contact lenses for large differences.
Adults: limit difference to about 2–3 D in spectacles if new; aniseikonia and prismatic effects (vertical imbalance at near: slab-off prism); contact lenses or refractive surgery.
Older patients
Small changes, keep the same lens design and base curves, avoid sudden changes in cylinder axis, careful near additions (lower adds for intermediate needs), single-vision distance glasses for walking (falls risk with bifocals and progressives).
Partial prescriptions and cylinder adaptation
New or larger cylinders cause distortion (tilted floors, walls): reduce cylinder and adjust sphere to keep the spherical equivalent, or move the axis toward 90° or 180°; minus cylinder form, aspheric designs, short vertex distance.
Myopic under-correction is not recommended for myopia control; hyperopes may be under-corrected when asymptomatic.
Abbe value: higher means less chromatic dispersion (CR-39 58, polycarbonate 30).
Coatings and treatments
Anti-reflective (multi-layer interference coatings: less glare and ghost images, better cosmesis), scratch resistant hard coat, hydrophobic and oleophobic layers, UV filters, mirror coatings.
Photochromic lenses: darken with UV; slow in cars (windscreen blocks UV), temperature-dependent.
Tints and polarised lenses: reduce glare from water and roads; not for night driving.
Blue-light filtering lenses: Cochrane review (2023) found no good evidence that they reduce eye strain, improve sleep or protect the macula.
Advice
Children and monocular patients: polycarbonate or Trivex for safety; high prescriptions: high-index, small frames, aspheric designs; outdoor workers: UV protection and polarised sunglasses; avoid over-selling coatings without evidence.
OP 25. Discuss the mechanism (and theories) of accommodation, lens changes during accommodation, range and amplitude, and methods of assessment of its anomalies. HIGH-YIELD· outline
Mechanism
Helmholtz theory (accepted): ciliary muscle contraction relaxes zonular tension, the elastic capsule lets the lens become more convex.
Lenticular: refractive lens exchange with multifocal, trifocal or EDOF IOLs.
Scleral and accommodating IOL approaches remain experimental.
OP 27. Spasm of accommodation; anomalies of convergence (insufficiency and excess). DNB / UNIV· outline
Spasm of accommodation
Excessive, sustained accommodation: pseudomyopia, blurred distance vision, headache, miosis, convergence (spasm of the near reflex: may be functional).
Causes: prolonged near work, uncorrected hyperopia, drugs (miotics), trauma, functional.
Treatment: cycloplegic drops, correct refraction, reassurance, reading glasses with cycloplegia.
Convergence insufficiency
Exophoria greater at near, receded near point of convergence (over 10 cm), reduced positive fusional vergence; asthenopia and diplopia with reading.
Treatment: office-based vergence therapy (CITT: most effective), pencil push-ups, base-in prisms for near, correct refractive error.
Convergence excess
Esophoria or esotropia greater at near; high AC/A ratio; treatment: plus add for near (bifocals), base-out prisms, surgery for large deviations.
OP 28. Pharmacological and surgical correction of presbyopia — presbyopia-correcting drops, corneal inlays, monovision and EDOF/multifocal IOLs. · outline
Pharmacological correction of presbyopia
Pilocarpine 1.25% (Vuity) and others: pupil constriction increases depth of focus (pinhole effect); side effects: headache, brow ache, poor dim-light vision, rare RD; lens-softening drops failed.
Corneal procedures
Corneal inlays (KAMRA small aperture, Raindrop: many withdrawn), presbyLASIK, monovision LASIK, conductive keratoplasty (historical).
Monovision
Dominant eye for distance, non-dominant for near (about −1.25 to −1.50 D): contact lenses, LASIK or IOLs; trial with contact lenses first; reduced stereopsis.
OP 29. Discuss the theories and recent concepts of the psychophysiology of colour vision, types of colour vision deficiency, and compare the tests available, including colour visual field examination. HIGH-YIELD· outline
Theories
Young–Helmholtz trichromatic theory (three cone types: S, M, L) at the receptor level.
Hering’s opponent process theory (red–green, blue–yellow, black–white) at the ganglion and LGN level; zone theory combines them.
Recent concepts
Cone photopigment genes (L and M on the X chromosome), parvocellular (red–green) and koniocellular (blue–yellow) pathways; cortical colour processing (V4).
Types of deficiency
Congenital: anomalous trichromats (protanomaly, deuteranomaly), dichromats (protanopia, deuteranopia, tritanopia), monochromats (rod, blue-cone); X-linked red–green in about 8% of males.
Acquired: red–green in optic nerve disease, blue–yellow in retinal and lens disease (Köllner’s rule).
Tests
Ishihara (screening red–green), Hardy–Rand–Rittler (includes tritan, quantifies), Farnsworth D-15 and 100-hue (classification and severity), Nagel anomaloscope (gold standard), City University test.
Colour visual fields: red targets in optic nerve and chiasmal disease (desaturation).
OP 30. Role of contrast sensitivity in ophthalmology — principles, methods of testing and clinical applications. HIGH-YIELD· outline
Principle
Contrast sensitivity is the ability to detect differences in luminance; the contrast sensitivity function (CSF) across spatial frequencies is more informative than acuity alone.
Methods
Pelli–Robson chart (letters of decreasing contrast), sine-wave gratings (Vistech, FACT), Mars letter chart, computerised tests.
Clinical applications
Reduced in cataract, glaucoma, optic neuritis, diabetic retinopathy, AMD and after refractive surgery; explains complaints with “6/6” vision; quality of vision after IOLs (multifocal), driving and low-vision assessment.
OP 31. Optics of contact lenses; selection, indications and contraindications. HIGH-YIELD· outline
Optics
Tear lens: the tear film behind an RGP lens corrects corneal astigmatism; vertex distance effect (power change for over ±4 D); smaller retinal image changes than spectacles (less aniseikonia, wider field).
Selection
Keratometry and topography, refraction, tear assessment, lid tension and occupation; trial fitting (central, apical clearance, movement).
Indications
Optical: high myopia, anisometropia, aphakia, irregular astigmatism (keratoconus).
Therapeutic: bandage, drug delivery. Cosmetic. Sports and occupational.
Contraindications
Dry eye, active infection or inflammation, blepharitis, poor hygiene, uncontrolled diabetes, dusty environment, inability to handle lenses.
OP 32. Types of contact lenses — RGP, soft, extended-wear, disposable, therapeutic/bandage and cosmetic lenses; safe contact-lens practice. HIGH-YIELD· outline
Types
RGP: oxygen permeable, sharp optics, keratoconus and astigmatism; scleral lenses for irregular corneas and ocular surface disease.
Soft hydrogel and silicone hydrogel (higher oxygen transmission); toric and multifocal designs.
Extended wear: higher microbial keratitis risk.
Disposable: daily (safest), fortnightly, monthly.
Therapeutic (bandage): epithelial defects, after PRK, bullous keratopathy, small perforations.
Cosmetic and prosthetic tinted lenses (iris printed); orthokeratology (reverse geometry).
Safe contact lens practice
Hand washing, no tap water or saliva, no sleeping in lenses unless prescribed, replace on schedule, fresh solution, case care, remove and seek help for a red eye (Acanthamoeba and Pseudomonas keratitis).
Special designs: Rose K, hybrid lenses (rigid centre, soft skirt), piggyback (RGP over soft lens), scleral and mini-scleral lenses (vault over the cornea: advanced keratoconus, post-keratoplasty, ocular surface disease).
Other indications: post-keratoplasty astigmatism, corneal scars, post-refractive surgery irregularity.
Orthokeratology
Reverse-geometry rigid lenses worn overnight to flatten the central cornea temporarily: corrects low to moderate myopia (up to about −4 to −6 D) during the day and slows myopia progression in children.
Risks: microbial keratitis (Pseudomonas, Acanthamoeba), need for strict hygiene.
Dry eye, superior limbic keratoconjunctivitis, limbal stem cell deficiency.
Prevention
Proper fitting, daily disposable lenses, avoid sleeping and swimming in lenses, rub and rinse cleaning, replace cases, regular review.
Low Vision & Rehabilitation
OP 35. What are low vision aids? Discuss their optical principles, indications and clinical applicability. HIGH-YIELD· outline
Definition
Devices that improve visual function in low vision (best-corrected acuity below 6/18 or field under 10° from fixation, but still potentially usable vision).
AMD, diabetic retinopathy, glaucoma, optic atrophy, albinism; training and motivation determine success; limitations include small field and working distance with higher magnification.
OP 36. WHO definitions of low vision; evaluation of a person with low vision and goals of visual rehabilitation. DNB / UNIV· outline
WHO definitions
Low vision (WHO, 1992 for services): best-corrected acuity in the better eye less than 6/18 to light perception, or visual field less than 10° from fixation, but who uses or could use vision for planning or doing a task.
ICD-11: moderate (worse than 6/18 to 6/60), severe (worse than 6/60 to 3/60) visual impairment, and blindness (worse than 3/60).
Maximise use of residual vision, achieve the patient’s goals (reading, mobility), independence in daily living, education and employment, psychological support, eccentric viewing training.
OP 37. Electronic and smartphone-based low vision devices and assistive technology. · outline
Electronic low vision devices
Video magnifiers (CCTV: desktop and portable), head-mounted electronic magnifiers (eSight, IrisVision), optical character recognition devices (OrCam), screen magnification and screen readers (JAWS, NVDA), audiobooks and talking devices.
Smartphone and tablet aids
Built-in accessibility (zoom, magnifier, VoiceOver and TalkBack, high-contrast modes, dictation), apps for text reading (Seeing AI, Envision, Google Lookout), object and currency recognition, navigation apps, remote assistance (Be My Eyes).
Advantages
High variable magnification, contrast enhancement, portability, affordable (often free apps); need training, battery, cost of dedicated devices.
Other assistive technology
Smart canes, GPS devices, Braille displays, accessible digital books (DAISY), artificial vision (retinal and cortical prostheses).
Questions: MD, MS and DNB ophthalmology theory question bank (subspecialty-wise compilation, 2026 edition), as recalled by candidates.
Answer outlines: written for this site from standard texts and the trials and classifications named in each answer.
📘 Want the exam-ready deep dive? This topic, and much more is covered in Ophthalmology Explorer (A High-Yield Clinical Reference for Ophthalmology Residents, Fellows & Board Exams) — available on Kindle. See all my books.
How to cite this page
Patel D. MD/MS/DNB Ophthalmology Theory Questions: Optics, Refraction and Low Vision (39 Questions with Answer Outlines). RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/md-ophthalmology-theory-questions-optics-refraction.html. Accessed [date].
Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy