Last updated: November 2026
Key points in 60 seconds
Eye Banking course: Course home · M1 · M2 · M3 · M4 · M5 · M6 · M7 · M8 · M9 · M10
Practise: Mock 1 · Mock 2 · Mock 3 · Viva and OSCE · Career guide
Exam map: Recovery: timing, preparation, aseptic technique, enucleation and in-situ excision, restoration of the body, documentation.
| Feature | Whole globe enucleation | In-situ corneoscleral excision |
|---|---|---|
| What is removed | Entire eyeball | Cornea with 2–4 mm scleral rim |
| Storage | Moist chamber at 2–8 °C; cornea excised later in the lab | Directly into storage medium (e.g. MK, Optisol-type) at 2–8 °C |
| Advantages | Sclera available; lab excision under laminar flow | Less disfigurement concern for families; immediate preservation |
| Disadvantages | Must be processed quickly; appearance concerns | Requires skill to avoid endothelial damage; less sclera |
Time of death, time of cooling (if any), time of retrieval (enucleation or excision), time of preservation in medium, and arrival at the eye bank. Death-to-preservation time is a key quality indicator.
Standard precautions, sharps safety, post-exposure protocol for needle-stick injuries, biomedical waste segregation (yellow and red bags, white sharps box as per Indian rules).
Enucleation removes the whole eye into a moist chamber; in-situ removes the corneoscleral rim directly into storage medium.
Eye caps or cotton in the socket, lids closed, face cleaned.
Death, cooling, retrieval, preservation, arrival at the bank.
It damages the endothelium.
In labelled containers in a cool box at 2–8 °C with temperature recorded.
Answer all, then press “Check my score”. Option order is mixed.
1. A moist chamber is used for:
Answer: Whole globes. Globe storage.
2. The scleral rim in in-situ excision is about:
Answer: 2–4 mm. For suturing.
3. Povidone-iodine 5% is applied to:
Answer: The ocular surface and lids. Asepsis.
4. Corneas in storage media are placed with the endothelium:
Answer: Up. Protect cells.
5. Death-to-preservation time is:
Answer: A key quality indicator. Affects cells.
6. Transport temperature for corneas is:
Answer: 2–8 °C. Cool box.
7. After enucleation, the optic nerve is cut:
Answer: Leaving a stump. Handling.
8. Needle-stick injury during retrieval requires:
Answer: Post-exposure protocol. Safety.
← M5. Donor Screening, Contraindications and Serology | M7. Tissue Evaluation: Slit Lamp, Specular Microscopy and Grading →
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
How to cite this page
Patel D. Eye Banking Module 6: Tissue Retrieval: Whole Globe and In-Situ Corneoscleral Excision. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/eye-bank-m6-tissue-retrieval-technique.html. Accessed [date].
Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.