Last updated: November 2026
Key points in 60 seconds
Eye Care Support Roles course: Course home · M1 · M2 · M3 · M4 · M5 · M6 · M7 · M8 · M9 · M10
Practise: Mock 1 · Mock 2 · Mock 3 · Viva and OSCE · Career guide
Exam map: For equipment engineers: electrical safety, preventive maintenance, phaco and vitrectomy systems, lasers, microscopes, OCT, autoclaves, documentation and vendor management.
| Equipment | Engineering points |
|---|---|
| Operating microscope | Illumination (LED/halogen/xenon), fibre optic cables, balance and brakes, foot pedal, camera; clean optics; check for light toxicity settings |
| Phaco and vitrectomy systems | Fluidics (pumps, sensors), handpiece tuning, power settings, footswitch, consumable cassettes; test cycles before lists |
| Ophthalmic lasers (YAG, green, diode, excimer, femtosecond) | Calibration of power/energy, aiming beam alignment, cooling, interlocks, gas supplies for excimer; Laser Safety Officer oversight |
| OCT, fundus camera, biometry | Software updates, calibration targets, network and storage, backups |
| Autoclaves | Water quality, door seals, sensors, validation (IQ/OQ/PQ), Bowie-Dick, leak tests, biological indicators |
| Slit lamps, tonometers, refraction units | Mechanical alignment, bulbs, calibration |
Medical devices are regulated under the Medical Devices Rules, 2017 (CDSCO); hospitals seeking NABH accreditation must show equipment management systems. Radiation-emitting devices are rare in eye care, but X-ray and CT follow AERB rules.
Protective earth resistance, insulation resistance, leakage currents, visual inspection.
AMC covers maintenance service; CMC also covers parts (comprehensive).
Installation, operational and performance qualification: validation stages.
A designated Laser Safety Officer with the department.
To plan maintenance, track history, manage warranties and replacements.
Answer all, then press “Check my score”. Option order is mixed.
1. IEC 62353 relates to:
Answer: Recurrent electrical safety testing of medical equipment. In-service testing.
2. Most surgical ophthalmic lasers are:
Answer: Class 4. Highest hazard.
3. Before opening equipment, engineers should:
Answer: Isolate power and lock out. Safety.
4. CMC includes:
Answer: Labour and parts. Comprehensive.
5. Phaco systems should be tested:
Answer: Before surgical lists. Readiness.
6. Medical devices in India are regulated under:
Answer: Medical Devices Rules, 2017. CDSCO.
7. Laser eyewear must match the:
Answer: Wavelength and optical density. Protection.
8. An asset register records:
Answer: Equipment details and service history. Management.
← M8. Equipment Care and Daily Checks (for Clinic Staff) | M10. Ethics, Law, Quality and Career Development →
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
How to cite this page
Patel D. Eye Care Support Roles Module 9: Biomedical Engineering for Eye Equipment. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/eye-care-support-m9-biomedical-engineering-eye-equipment.html. Accessed [date].
Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.