ERG, EOG and VEP Practice: 22 Simulated Electrophysiology Reports

ERG, EOG and VEP Practice: 22 Simulated Electrophysiology Reports

For: PG residents · Practising ophthalmologists

Last updated: November 2026

Key points in 60 seconds

  • Twenty-two simulated ISCEV-style ERG, EOG, PERG, mfERG and VEP reports.
  • DA 0.01 tests rods; LA 3.0 and 30 Hz flicker test cones.
  • A b-wave smaller than the a-wave is a negative ERG (inner retina).
  • PERG separates macular (P50) from ganglion cell (N95) dysfunction.
  • VEP delay suggests demyelination; reduced amplitude suggests axonal loss.

Twenty-two simulated electrophysiology reports in ISCEV style: full-field ERG, EOG, pattern ERG, multifocal ERG and pattern VEP, each with traces and a values table. Read each one in the atlas, test yourself in the quiz, or sit a timed set of 20.

Part of the Diagnostics Lab: computer-drawn practice reports with step-by-step explanations. Simulations for teaching, not real patients.

How to read it in six steps

  1. Which test: full-field ERG (whole retina), PERG and mfERG (macula), EOG (RPE), VEP (whole pathway to cortex).
  2. Rods vs cones: DA 0.01 is rod-only; LA 3.0 and 30 Hz flicker are cone responses.
  3. a-wave vs b-wave: a-wave = photoreceptors; b-wave = bipolar cells. b smaller than a = negative ERG.
  4. Timing: delayed responses (especially flicker and VEP P100) matter as much as size.
  5. Compare eyes: asymmetry suggests a local (vascular, toxic, inflammatory) cause.
  6. Put together: ERG normal + PERG abnormal = macula; PERG P50 normal + N95 low = ganglion cells.

Practise

Quick reference

PatternThink of
Rods worse than conesRetinitis pigmentosa
Cones only reducedCone dystrophy, achromatopsia
Negative ERGCSNB, X-linked retinoschisis, CRAO, MAR
Everything extinguished in infancyLeber congenital amaurosis
Low EOG, normal ERGBest disease
Delayed P100, near-normal amplitudeDemyelinating optic neuritis

Related: electrophysiology made easy, the electrophysiology reference and EOG.

Key sources

  • Robson AG, et al. ISCEV Standard for full-field clinical electroretinography (2022 update). Doc Ophthalmol. 2022;144:165–177.
  • Odom JV, et al. ISCEV standard for clinical visual evoked potentials (2016 update). Doc Ophthalmol. 2016;133:1–9.
  • Constable PA, et al. ISCEV Standard for clinical electro-oculography (2017 update). Doc Ophthalmol. 2017;134:1–9.

📘 Want more exam-ready material? See Most Commons in Ophthalmology on Kindle, or browse all my books.

How to cite this page

Patel D. ERG, EOG and VEP Practice: 22 Simulated Electrophysiology Reports. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/erg-eog-vep-practice-interpretation.html. Accessed [date].

Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy

Consultant, Cataract & Refractive Surgery — among a small number of AIIMS-trained ophthalmologists practicing in Gujarat. Read full credentials & experience or view his 28 publications on ResearchGate.

📚 Also the author of OKAT Decoded, FRCOphth Decoded, FICO Decoded, OKAP & ABO Decoded, FEBO Decoded and other high-yield ophthalmology exam-prep books used by residents and PG aspirants.

Looking for an eye specialist in Ahmedabad? Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.