Infection Control in the Eye Clinic and Theatre: Tonometers, Drops, Sterilisation, Endophthalmitis Clusters and Waste

Infection Control in the Eye Clinic and Theatre: Tonometers, Drops, Sterilisation, Endophthalmitis Clusters and Waste

Last updated: November 2026

Key points in 60 seconds

  • Hand hygiene between every patient is the single most effective measure.
  • Tonometer prisms and contact lenses (gonio, laser) must be cleaned and disinfected between patients, or single-use tips used.
  • Multi-dose drop bottles should not touch the eye; separate bottles for infected patients, and discard on the date the label specifies after opening.
  • Sterilisers need monitoring: chemical indicators in every pack, a Bowie-Dick test daily for prevacuum autoclaves and biological indicators at least weekly.
  • Two or more endophthalmitis cases close together is a possible cluster: stop, review and investigate before the next list.

OPD checklist

ItemPractice
HandsAlcohol rub or hand wash before and after each patient (WHO five moments)
Slit lamp and chin restWipe chin rest, forehead band and handles between patients with an alcohol or detergent wipe; use disposable chin-rest paper
Goldmann tonometer prismsWipe clean, then disinfect (for example soak in 70% alcohol or a dilute hypochlorite solution as per your protocol), rinse and dry; or use single-use prisms. Remove all disinfectant before use
Gonioscopy and laser lensesClean coupling gel promptly, then disinfect as the manufacturer advises
Contact tonometers (rebound, pen)Single-use probes or covers
Multi-dose dropsDo not touch lashes; date on opening; keep separate bottles for infected eyes; discard as per label
Trial frames and lenses, occludersWipe between patients
Adenoviral conjunctivitisSee in a separate area; gloves; disinfect equipment and surfaces after the patient; staff with conjunctivitis stay off clinical work until resolved

Theatre checklist

AreaPractice
Instrument cleaningClean immediately after use; ultrasonic cleaning where suitable; flush cannulas; final rinse with sterile or purified water to avoid toxic anterior segment syndrome (TASS) from detergent or residues
SterilisationSteam autoclave (commonly 121 degrees C for at least 15 minutes, or 134 degrees C for 3 to 4 minutes); avoid routine immediate-use ("flash") cycles
MonitoringChemical indicator in and on every pack; Bowie-Dick test each morning for prevacuum autoclaves; biological indicator (Geobacillus stearothermophilus) at least weekly and after repairs; keep load records
Single-use itemsPhaco tips, sleeves and cannulas labelled single use should not be reprocessed unless validated
AntisepsisPovidone-iodine 5% in the conjunctival sac and 10% on the skin, with adequate contact time; chlorhexidine 0.05% if iodine allergy
Intracameral antibioticUse commercial preparations or carefully prepared dilutions; see intracameral drugs guide
Theatre air and trafficMaintain ventilation and filtration as designed; keep doors closed; limit people in theatre

If endophthalmitis cases cluster

Response

  1. Stop the next list if two or more cases occur close together until a review is done.
  2. Collect vitreous and aqueous samples for culture before antibiotics; inform microbiology.
  3. List common factors: date, theatre, surgeon, staff, solutions, viscoelastic, IOL batch, sterilisation loads.
  4. Culture suspected sources (fluids, equipment) with the microbiologist; check steriliser records.
  5. Report to the hospital infection committee and, if a product is suspected, to the manufacturer and regulator.

Biomedical waste (India)

ColourContents
YellowHuman anatomical waste, soiled dressings and cotton, discarded medicines, chemical waste
RedContaminated recyclable plastics: tubing, syringes without needles, gloves, catheters
White (translucent, puncture-proof)Sharps: needles, blades, broken metal sharps
Blue (cardboard box)Glassware, including broken glass and empty glass vials

Follow the Biomedical Waste Management Rules, 2016 (with amendments) and your state pollution control board requirements.

Key sources

  • Centers for Disease Control and Prevention. Guideline for Disinfection and Sterilization in Healthcare Facilities. 2008 (updated)
  • Royal College of Ophthalmologists. Ophthalmic Instrument Decontamination guidance
  • Ministry of Environment, Forest and Climate Change. Bio-Medical Waste Management Rules, 2016
  • American Society of Cataract and Refractive Surgery and American Academy of Ophthalmology. Recommendations for reprocessing intraocular surgical instruments (TASS)

📘 Want more exam-ready material? See Most Commons in Ophthalmology on Kindle, or browse all my books.

How to cite this page

Patel D. Infection Control in the Eye Clinic and Theatre: Tonometers, Drops, Sterilisation, Endophthalmitis Clusters and Waste. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/eye-clinic-infection-control-sterilisation-checklist.html. Accessed [date].

Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy

Consultant, Cataract & Refractive Surgery — among a small number of AIIMS-trained ophthalmologists practicing in Gujarat. Read full credentials & experience or view his 28 publications on ResearchGate.

📚 Also the author of OKAT Decoded, FRCOphth Decoded, FICO Decoded, OKAP & ABO Decoded, FEBO Decoded and other high-yield ophthalmology exam-prep books used by residents and PG aspirants.

Looking for an eye specialist in Ahmedabad? Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.