The eye operation theatre runs on teamwork. Surgeons can operate quickly and safely only when the OT assistant has prepared the room, instruments, machines and patient well. This guide covers the essentials for new OT assistants and scrub technicians.
OT discipline and asepsis
Respect the zones: unrestricted (changing, reception), semi-restricted (corridors, sterile store) and restricted (operating room). OT dress, cap and mask in restricted areas.
Hand hygiene at the five moments; surgical scrub before gowning (for example 3–5 minutes with an approved scrub, or an alcohol-based surgical rub as per policy).
Keep doors closed and movement minimal; every opening disturbs air flow.
Check sterile packs for intact wrapping, dry packs, indicator change and expiry before opening.
Clean surfaces between cases and do a terminal clean at the end of the day.
Instrument care and sterilisation
Point of use: wipe blood and viscoelastic off instruments with sterile water during and immediately after the case; do not let material dry.
Flush cannulas and handpieces (phaco, I/A, irrigation cannulas) with sterile water straight after surgery as per the manufacturer's instructions, then with air.
Clean: use enzymatic detergent only if the manufacturer allows, followed by thorough rinsing with sterile or deionised water. Residue of detergent or denatured viscoelastic is a known cause of TASS.
Inspect under magnification: bent tips, damaged blades, rust or residue.
Sterilise by the validated method: steam autoclave for most metal instruments; low-temperature methods (ethylene oxide or hydrogen peroxide plasma) for heat-sensitive items. "Flash" (immediate-use) sterilisation should not be the routine.
Record every load: chemical indicators each pack, Bowie-Dick test for pre-vacuum autoclaves daily, biological indicators as per policy, and load numbers traceable to patients.
Single-use items (blades, cannulas marked single use, IOL injectors) are never reprocessed.
Setting up for cataract surgery
Phaco machine: switch on and self-test, correct pack and tubing, prime and tune the handpiece, check irrigation bottle height or pressure settings as the surgeon prefers, foot pedal position and cable away from feet.
Microscope: clean optics, balance, focus and zoom centred, foot pedal working, bulb spare available, eyepieces set for the surgeon.
Trolley: speculum, blades (keratome, side-port), viscoelastic, trypan blue if planned, cystitome or forceps, chopper, I/A, IOL and injector, BSS, intracameral antibiotic if used (exact dilution as per protocol, labelled).
Patient: identity, consent, correct eye marked, allergy and blood thinner check, pupil dilated, anaesthesia as planned, position comfortable with the head stable, drape with lashes tucked away.
Safety checklist: the moments that matter
Moment
What the team confirms
Before anaesthesia (sign in)
Patient identity, procedure, eye marked, consent, allergies, anticoagulants, diabetes, any previous refractive surgery
Before incision (time out)
Correct patient and eye; IOL model and power read aloud and matched to the biometry sheet; a backup IOL available; equipment working
Before leaving (sign out)
Procedure recorded, IOL sticker on records, instruments and sharps counted, specimens labelled, post-op drops and instructions given
Emergencies to be ready for
Vasovagal faint or anxiety: talk to the patient, monitor pulse and oxygen, inform the anaesthetist or surgeon.
Allergic reaction (including to fluorescein or drugs): resuscitation trolley and adrenaline ready and checked daily.
Posterior capsule rupture: be ready with anterior vitrectomy settings and cutter, triamcinolone if used, a 3-piece IOL or AC IOL as the surgeon decides.
Power failure: know where the backup and the manual instruments are.
Sharps injury: wash with soap and water, report immediately and follow the post-exposure protocol.
Biomedical waste (India)
Container
What goes in
Yellow bag
Soiled dressings, cotton, swabs and drapes contaminated with blood or body fluids; anatomical waste; discarded medicines
Red bag
Contaminated recyclable plastics: tubing, gloves, syringes without needles, IV sets
White puncture-proof container
Needles, blades, scalpels and other sharps
Blue box or container
Glassware and metallic implants
Follow your hospital's policy and the current Bio-Medical Waste Management Rules. Next: practical and viva questions.
Revise with flip cards
Key sources
ASCRS/AAO. Recommended practices for cleaning and sterilizing intraocular surgical instruments (2018 update)
WHO Surgical Safety Checklist (2009) and its ophthalmic adaptations
Bio-Medical Waste Management Rules, 2016 (India)
Mamalis N et al. Toxic anterior segment syndrome. J Cataract Refract Surg 2006
New for optometrists: OptomDecoded
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
Patel D. Eye OT Assistant and Ophthalmic Scrub Technician Guide: Sterilisation, Set-Up, Phaco Machine, Microscope and Safety. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/eye-ot-assistant-guide.html. Accessed [date].
Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy