Key points in 60 seconds
Ocularistry course: Course home · M1 · M2 · M3 · M4 · M5 · M6 · M7 · M8 · M9 · M10
Practise: Mock 1 · Mock 2 · Mock 3 · Viva and OSCE · Career guide
Exam map: Patient care: insertion and removal, cleaning, infection control, managing discharge and irritation, follow-up schedules.
| Step | Insertion | Removal |
|---|---|---|
| 1 | Wash hands; moisten prosthesis | Wash hands; work over a soft towel |
| 2 | Hold with notch/marked side correctly oriented (usually the narrow pointed end towards the nose) | Look up; pull lower lid down |
| 3 | Lift upper lid; slide the upper edge up under it | Press lower lid gently inward and upward at the lower edge, or use a small suction cup |
| 4 | Pull lower lid down; let the lower edge slip behind it | Let the prosthesis slide out into the hand |
| 5 | Check position; blink | Clean and store moist or reinsert |
| Problem | Likely cause | Action |
|---|---|---|
| Mucoid discharge | Deposits, rough surface, over-handling, allergy | Clean, professional polish, reduce handling, lubricants, check fit |
| Purulent discharge, pain, swelling | Infection | Medical review; swab; antibiotics |
| Prosthesis rotates or falls out | Shallow fornix, lax lower lid, poor fit | Refit; refer for lid tightening or fornix surgery |
| Lid irritation, crusting | Blepharitis, dryness | Lid hygiene, lubricants |
| Giant papillary conjunctivitis | Deposit reaction | Polish, reduce wear briefly, anti-allergy drops |
| Implant exposure | Pressure, thin tissue | Refer urgently; modify back surface |
| Upper lid droop or deep sulcus | Volume loss | Modify prosthesis; refer for surgery |
Patient leaflet: caring for your artificial eye.
Wash hands, look up, pull lower lid down, press under the lower edge to let it slide out into the hand (or use a suction cup).
Over-handling irritates the socket and increases discharge.
Same-day medical review for infection.
Alcohol, solvents, abrasives or boiling water.
About yearly with polishing, plus the remaining eye checked.
Answer all, then press “Check my score”. Option order is mixed.
1. When inserting, the first edge to go in is usually the:
Answer: Upper edge under the upper lid. Then lower lid.
2. Frequent daily removal often causes:
Answer: More irritation and discharge. Handle less.
3. A suction cup is used for:
Answer: Removal. Easier removal.
4. Mucoid discharge is commonly due to:
Answer: Deposits and rough surfaces. Polish.
5. Purulent discharge with fever needs:
Answer: Medical review. Infection.
6. Wiping the prosthesis in place should be:
Answer: Towards the nose. Avoid rotation.
7. Swimming with a prosthesis is safer with:
Answer: Goggles. Prevent loss.
8. The remaining eye should be checked:
Answer: About yearly. Protect sight.
← M8. Scleral Shells, Conformers and Special Cases | M10. Photography, Records, Ethics and Professional Practice →
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
How to cite this page
Patel D. Ocularistry Module 9: Socket Care, Hygiene, Complications and Follow-Up. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/ocularist-m9-socket-care-hygiene-complications-follow-up.html. Accessed [date].
Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.