Ophthalmic Imaging Module 4: Anterior Segment, External and Gonio Photography

For: Allied eye-care staff

Last updated: November 2026

Key points in 60 seconds

  • Slit-lamp photography combines illumination technique, magnification and background light to show the lesion clearly.
  • External photos: standard views (primary gaze, gazes, profile), consistent background and lighting, scale reference.
  • Gonio photography needs a gonioscopy lens and coupling gel; angle structures are photographed in each quadrant.
  • Smartphone adapters are practical but require consent, secure storage and consistent technique.

Ophthalmic Imaging course: Course home · M1 · M2 · M3 · M4 · M5 · M6 · M7 · M8 · M9 · M10

Practise: Mock 1 · Mock 2 · Mock 3 · Viva and OSCE · Career guide

Exam map: Slit-lamp photography, external and facial photography, gonio photography, specular and corneal imaging, smartphone imaging.

Slit-lamp photography

  • Choose the illumination (Module 2) to suit the lesion: diffuse for overview, slit for depth, retro for lens opacities, cobalt blue with fluorescein for staining.
  • Use background illumination to show context; adjust beam angle to avoid reflections.
  • Take an overview first, then details at higher magnification.
  • Fluorescein staining: instil dye, wait, use cobalt blue with a yellow barrier filter on the camera for best contrast.

External and facial photography

ViewUse
Primary gaze, both eyes, eyebrow to cheekPtosis, lid position, proptosis
Nine gaze positionsStrabismus and motility
Profile and worm’s-eye (chin up) viewsProptosis
Close-up of lesion with rulerLid tumours, size
Before and after surgerySame lighting, distance, head position

Use a plain neutral background, even lighting, the same camera distance and head position, and a scale. Remove spectacles unless needed.

Gonio photography

  • Topical anaesthetic; gonio lens with coupling gel (or non-coupling lens); dim room; patient looks straight.
  • Photograph each quadrant; identify Schwalbe line, trabecular meshwork, scleral spur, ciliary body band; note pigment, synechiae, new vessels, recession.
  • Clean and disinfect the lens after each patient.

Corneal and endothelial imaging

  • Specular microscopy: endothelial cell density and shape (see reference).
  • Confocal microscopy: corneal layers in vivo (Acanthamoeba cysts, fungal hyphae, nerves).
  • Corneal topography and tomography (Module 9).

Smartphone imaging

  • Slit-lamp adapters and handheld fundus attachments; quick documentation and teleconsultation.
  • Consent, secure institutional storage (not personal galleries or messaging apps), de-identification for teaching.

Practice questions (short answer and viva)

Which illumination shows a posterior subcapsular cataract best?

Retro-illumination.

What views are taken for ptosis documentation?

Primary gaze, up and down gaze, close-up of lids with a scale.

What structures are identified on gonio photos?

Schwalbe line, trabecular meshwork, scleral spur, ciliary body band.

Why use a yellow barrier filter for fluorescein slit-lamp photos?

It blocks blue light and enhances the green fluorescence.

How should smartphone clinical images be stored?

In secure institutional systems with consent, not in personal galleries or messaging apps.

Self-test: 8 MCQs

Answer all, then press “Check my score”. Option order is mixed.

1. A ruler in external photos provides:

Show answer

Answer: Scale. Measurement.

2. Before-and-after photos should use:

Show answer

Answer: Identical lighting, distance and position. Comparison.

3. Gonio photography requires:

Show answer

Answer: A gonioscopy lens. Angle view.

4. Confocal microscopy can show:

Show answer

Answer: Acanthamoeba cysts and fungal hyphae. Cornea.

5. Fluorescein-stained epithelial defects appear:

Show answer

Answer: Green under cobalt blue. Staining.

6. Proptosis is best shown by:

Show answer

Answer: Profile and worm's-eye views. Projection.

7. A gonio lens should be:

Show answer

Answer: Cleaned and disinfected after each patient. Infection control.

8. Clinical photos shared on personal messaging apps:

Show answer

Answer: Breach privacy policies. Security.

Revise with flip cards

Key sources

  • Ophthalmic Photographers’ Society certification information
  • Saine and Tyler, Ophthalmic Photography
  • Spaide RF et al. Optical coherence tomography angiography. Prog Retin Eye Res 2018
  • Digital Personal Data Protection Act 2023 (India)
OptomDecoded: Comprehensive Optometry book cover

New for optometrists: OptomDecoded

5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.

How to cite this page

Patel D. Ophthalmic Imaging Module 4: Anterior Segment, External and Gonio Photography. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/ophthalmic-imaging-m4-anterior-segment-external-gonio-photography.html. Accessed [date].

Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy

Consultant, Cataract & Refractive Surgery — among a small number of AIIMS-trained ophthalmologists practising in Gujarat. Read full credentials & experience or view his 28 publications on ResearchGate.

📚 Also the author of OptomDecoded (optometry licensing exams), OKAT Decoded, FRCOphth Decoded, FICO Decoded, OKAP & ABO Decoded, FEBO Decoded and other high-yield ophthalmology exam-prep books used by residents and PG aspirants.

Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.