Ophthalmic Imaging Module 7: OCT Angiography (OCTA)

For: Allied eye-care staff

Last updated: November 2026

Key points in 60 seconds

  • OCTA detects blood flow by motion contrast between repeated scans at the same location: no dye needed.
  • It shows vessels in slabs (superficial, deep capillary plexus, outer retina, choriocapillaris) but cannot show leakage.
  • Projection artefacts, motion and segmentation errors are common; always check structural B-scans with flow overlay.
  • Uses: CNV detection, diabetic non-perfusion and FAZ, vein occlusion, glaucoma disc perfusion.

Ophthalmic Imaging course: Course home · M1 · M2 · M3 · M4 · M5 · M6 · M7 · M8 · M9 · M10

Practise: Mock 1 · Mock 2 · Mock 3 · Viva and OSCE · Career guide

Exam map: OCTA principles, slabs, artefacts and clinical uses.

How OCTA works

  • Multiple B-scans are taken at each position; moving red blood cells change the signal (decorrelation), static tissue does not.
  • Algorithms (e.g. SSADA, OMAG, split-spectrum) create flow images; slabs are defined by segmentation boundaries.
  • Scan sizes: 3×3 mm (high detail), 6×6 mm, wider montages; larger areas have lower density of sampling.

Standard slabs

SlabWhat it shows
Superficial capillary plexusRNFL/GCL vessels; FAZ outline
Deep capillary plexusINL/OPL vessels; diabetic and vein occlusion changes
Avascular outer retinaNormally no vessels: flow here suggests CNV (type 2/3)
ChoriocapillarisFlow voids; type 1 CNV networks just above
Radial peripapillary capillariesDisc perfusion in glaucoma

Artefacts

ArtefactDescription
ProjectionSuperficial vessels appear in deeper slabs; projection-removal algorithms help
Motion (lines, doubling)Eye movements; use tracking
Segmentation errorsPathology distorts layer boundaries; slabs wrong
ShadowingMedia opacities, haemorrhage, pigment cause flow voids
Low signalAs for OCT

Clinical uses

  • Neovascular AMD: CNV networks; non-exudative CNV.
  • Diabetic retinopathy: enlarged irregular FAZ, capillary dropout, microaneurysms, intraretinal microvascular abnormalities, neovascularisation (widefield OCTA).
  • Vein and artery occlusions: non-perfusion areas.
  • Glaucoma and optic neuropathies: peripapillary vessel density.
  • Limitations: no leakage, staining or pooling information; small field; artefacts; quantitative metrics differ between devices.

Go deeper: angiography practice.

Practice questions (short answer and viva)

How does OCTA detect flow?

By motion contrast (decorrelation) between repeated B-scans at the same location.

What can FFA show that OCTA cannot?

Leakage, staining and pooling.

What is projection artefact?

Superficial vessel patterns appearing falsely in deeper slabs.

Which slab is normally avascular?

The outer retina.

Name two OCTA findings in diabetic retinopathy.

Enlarged irregular FAZ and capillary non-perfusion (also microaneurysms, IRMA).

Self-test: 8 MCQs

Answer all, then press “Check my score”. Option order is mixed.

1. OCTA requires:

Show answer

Answer: No dye. Non-invasive.

2. Flow in the outer retina slab suggests:

Show answer

Answer: CNV. Abnormal.

3. OCTA cannot show:

Show answer

Answer: Leakage. Static image of flow.

4. A 3×3 mm scan compared with 6×6 mm gives:

Show answer

Answer: Higher detail over a smaller area. Sampling density.

5. Shadowing artefacts come from:

Show answer

Answer: Haemorrhage or media opacity. Signal blockage.

6. Radial peripapillary capillaries are studied in:

Show answer

Answer: Glaucoma. Disc perfusion.

7. Projection removal algorithms address:

Show answer

Answer: Projection artefacts. Deeper slabs.

8. Quantitative OCTA metrics between devices are:

Show answer

Answer: Not directly comparable. Device-specific.

Revise with flip cards

Key sources

  • Ophthalmic Photographers’ Society certification information
  • Saine and Tyler, Ophthalmic Photography
  • Spaide RF et al. Optical coherence tomography angiography. Prog Retin Eye Res 2018
  • Digital Personal Data Protection Act 2023 (India)
OptomDecoded: Comprehensive Optometry book cover

New for optometrists: OptomDecoded

5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.

How to cite this page

Patel D. Ophthalmic Imaging Module 7: OCT Angiography (OCTA). RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/ophthalmic-imaging-m7-oct-angiography.html. Accessed [date].

Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy

Consultant, Cataract & Refractive Surgery — among a small number of AIIMS-trained ophthalmologists practising in Gujarat. Read full credentials & experience or view his 28 publications on ResearchGate.

📚 Also the author of OptomDecoded (optometry licensing exams), OKAT Decoded, FRCOphth Decoded, FICO Decoded, OKAP & ABO Decoded, FEBO Decoded and other high-yield ophthalmology exam-prep books used by residents and PG aspirants.

Want to know more about treatment? Read about the Eye Department at Sadbhaav or book a consultation with Dr. Dhaval Patel.