Each list is a marking checklist: introduce yourself, identify the patient, explain, gain consent and wash hands at the start of every station, and document at the end.
Fundus photography (macula and disc fields)
Verify patient and eye; explain flash.
Dilate as ordered; adjust chin rest and height.
Align to pupil; set working distance (no crescents); focus on vessels.
Capture macula- and disc-centred fields; check quality immediately.
Label and save; note artefacts or ungradable images.
OCT macular cube and RNFL scan
Enter correct patient data including date of birth.
Ask patient to blink; align; adjust focus and polarisation.
Centre on fovea or disc; enable tracking; capture.
Check signal strength, centration and segmentation on B-scans.
Repeat if needed; use follow-up mode for comparisons.
Preparing and performing FFA
Confirm order and consent; take history (allergy, asthma, pregnancy, kidney).
Dilate; insert cannula; emergency kit and doctor available.
Colour and red-free baseline photos; set filters and timer.
Inject dye; capture early sequence then mid and late phases.
Monitor patient; manage nausea; advise on yellow skin and orange urine; document.
B-scan ultrasound
Explain; patient lying or reclined; gel on closed lids.
Transverse and longitudinal scans in each quadrant.
Dynamic scans with eye movements to judge mobility.
Adjust gain; label images; report findings to clinician.
Optical biometry
Remove contact lenses as per protocol; check tear film.
Measure both eyes; check signal quality and consistency.
Compare inter-eye differences; re-measure if over limits.
Record and transfer data correctly; note previous refractive surgery.
Viva questions
Name the FFA phases.
Choroidal, arterial, arteriovenous, venous, late.
What is a window defect?
Early hyperfluorescence through RPE atrophy that fades without changing size.
How does OCT work?
Low-coherence interferometry measuring echo time delay of reflected light.
How does OCTA differ from FFA?
OCTA shows flow without dye but no leakage; FFA shows leakage, staining and pooling.
What is fundus autofluorescence?
Imaging of natural RPE lipofuscin fluorescence.
Name common fundus photo artefacts.
Crescents, lid shadows, dust spots, blur, dark images.
What are the advantages of swept-source OCT?
Faster, deeper penetration, better choroid and through cataract.
What is the role of red-free imaging?
To enhance vessels, haemorrhages and nerve fibre defects.
Signal strength, centration, segmentation on B-scans, motion artefacts.
When should biometry be repeated?
Large inter-eye differences, poor signals, unusual values.
What is projection artefact in OCTA?
Superficial vessels appearing in deeper slabs.
What emergency drugs are needed for angiography?
Adrenaline, antihistamine, steroid, oxygen and resuscitation equipment.
Revise with flip cards
Key sources
Ophthalmic Photographers’ Society certification information
Saine and Tyler, Ophthalmic Photography
Spaide RF et al. Optical coherence tomography angiography. Prog Retin Eye Res 2018
Digital Personal Data Protection Act 2023 (India)
New for optometrists: OptomDecoded
5,885 original MCQs, 150 OSCE stations and 800 viva questions for optometry licensing exams (NBEO, OCANZ, OEBC, UK and India), every option explained with a "why not" and a pearl.
Patel D. Ophthalmic Imaging Viva and OSCE: Skill Checklists and Questions. RPC Rounds (Sadbhaav Eye Clinic). Updated November 2026. Available at: https://www.sadbhaavclinic.com/ophthalmic-imaging-viva-osce.html. Accessed [date].
Written and medically reviewed by Dr. Dhaval Patel, MD (Ophthalmology, AIIMS New Delhi) · Editorial policy