Every phaco surgeon was once a beginner with shaking hands. This page breaks phacoemulsification into its steps, explains the purpose of each one, and lists the most common beginner mistakes and how to avoid them.
Remember: a good phaco is built on a good capsulorhexis and a stable chamber. Speed comes later, by itself.
Before you start
- Know your patient: pupil size after dilation, pseudoexfoliation, anterior chamber depth, nuclear density, and previous surgery.
- Check the biometry and the IOL in theatre before you begin.
- Position the patient and microscope so you are comfortable. A tense surgeon has tense hands.
- Apply povidone-iodine 5% and drape the lashes completely out of the field.
Step-by-step
- Incisions: a side port (paracentesis) and a main clear corneal incision (typically 2.2–2.8 mm). A good main incision has a tunnel long enough to self-seal. Too short a tunnel leads to iris prolapse and leaks; too long a tunnel causes corneal striae and poor view.
- Viscoelastic (OVD): fill the anterior chamber to flatten the anterior capsule and protect the endothelium. Dispersive OVDs coat the endothelium; cohesive OVDs maintain space. The "soft-shell" technique uses both.
- Capsulorhexis: aim for a central, round, continuous tear of about 5–5.5 mm that overlaps the IOL optic edge. Re-grasp often and keep the flap close to the centre. In white cataracts, stain the capsule with trypan blue.
- Hydrodissection: inject fluid gently under the capsule edge until you see a fluid wave, then confirm the nucleus rotates freely. Avoid forceful hydrodissection in posterior polar cataracts.
- Nucleus removal: divide and conquer (sculpt grooves, crack, then emulsify quadrants) is the usual beginner technique. Chop techniques use less energy and become more useful with harder nuclei. See phaco chop techniques.
- Cortex removal (I/A): engage cortex under the capsule edge, pull it towards the centre, then aspirate. Subincisional cortex is the hardest; a bimanual I/A or a curved tip helps.
- IOL implantation: refill with OVD and inject the lens into the bag. Make sure both haptics are in the bag and the optic is centred.
- OVD removal and closure: remove viscoelastic from behind and in front of the IOL to prevent a post-operative IOP spike. Hydrate the wounds and confirm they are watertight.
Understand your machine settings
- Power emulsifies the nucleus. Use it efficiently; excess energy damages the endothelium.
- Vacuum holds the nuclear fragment on the tip. Low vacuum for sculpting, high vacuum for chopping and quadrant removal.
- Aspiration flow controls how quickly fragments come to the tip and how lively the chamber feels.
- Bottle height or infusion pressure maintains the chamber. Too low and the chamber collapses (surge); too high and the chamber is deep and uncomfortable for the patient.
Common beginner problems
| Problem | Usual cause | What to do |
| Iris prolapse | Incision too posterior or too short, overfilled chamber, high pressure behind the lens | Reduce OVD, reposit the iris through the side port, consider a new incision |
| Capsulorhexis running out to the periphery | Shallow chamber with a positive pressure pushing the lens forward | Stop, refill with OVD, and use the Little manoeuvre (unfold the flap and pull it back towards the centre) |
| Shallow, unstable chamber | Low infusion, wound leak, or high aspiration flow | Raise the bottle or infusion pressure, check the wound, reduce the flow |
| Corneal burn at the incision | Tight incision, poor flow, prolonged high power | Ensure good flow and a correctly sized incision; reduce power |
| Posterior capsule rupture | Many causes; most common during nucleus and cortex removal | Recognise the signs early (sudden deepening of the chamber, a fragment that won't follow, a visible capsule defect). Do not withdraw the probe until the chamber has been filled with OVD. See the PCR management flowchart. |
Building your skills
- Practise on a wet lab or simulator before and alongside live surgery.
- Record your operations and review them with a mentor. Every video teaches more than you think.
- Learn one technique well before learning many.
- Start with easy cases: good dilation, moderate nucleus, deep chamber, cooperative patient.